Service & Support

Our Limited-Time Free Repair Program

Help for healing hands is one of Sense Technology’s main priorities. One way we believe  we can help is by introducing a limited time free repair program. This program will only require that you pay shipping to and from us (in our headquarters office near Harrisburg, PA.) All repairs in the continental U.S. and Canada will be free of charge.

We’ve started the program after reconnecting with our doctors and confirming that most doctors are all seeing drastically reduced income, and believe in a small way maybe we can help prepare our doctors for the strongest possible comeback.

This Free Repair Program is good for the foreseeable future during these difficult times.

Our Regular Support Policy

If you have a question regarding your The PulStar, please feel free to call us during normal business hours at 1.800.628.9416 or 724.733.2277 Monday thru Friday 9 AM – 5 PM Eastern time.  If you require assistance after hours, email us at techsupport@pulstar.us and we will get back to you as soon as possible.  We do check the support email regularly after hours and on week-ends.  Please include The PulStar and Impulse Head serial number and any problem information at the time of call or email.  You can find the Impulse Head serial number where the cord plugs into The PulStar and The PulStar serial number on the bottom or back of The PulStar box itself.

There is no support cost during The PulStar warranty period.  After the warranty period, you can get free support via the email address above. Phone support is available at a rate of $75 US per hour with a minimum of 1 hour at the time of the call.  Please have your credit card available at the time of the call.

Sense Technology also offers a loaner program currently at no additional cost while under warranty.  If we are unable to solve the problem over the phone, we will send a loaner system overnight in the contiguous United States. This service excludes the computer shipped with The PulStar

Please give us your information to get limited time free repairs in the continental U.S. or Canada.

Frequently Asked Questions

Cleaning the PulStar between patients is very simple. It is recommended that you use at least 70% Isopropyl Alcohol solution to wipe down the grey tips of the PulStar attachments between patients. The aluminum parts of the PulStar may be wiped down as well. The tips are made from FDA approved Food Grade Silicone. If they become hard over time, replacement tips can be purchased from Sense Technology.

The PulStar can be used in the Prone, Seated or Standing positions. You can set the expected value line to any of the three positions for the patient before starting the analysis process.

There are 7 force settings available for the adjust mode (5,10,15,20,25,30,35) and 3 settings for the analysis mode (5,10,15). It is recommended that you choose the lowest force available depending on the patient type and area being adjusted.

The preload is a very light 2 – 4 pounds depending on the force level currently selected. 5 – 10 pounds force is a low preload, 15 – 20 pounds force is a medium preload and 25 – 35 pounds force is a high preload setting meaning it will take more force to initiate an impulse. The preload pressure is changed automatically when the force level is selected.

The PulStar adjustment rate can be set anywhere between 2 and 22 impulses per second. The Point mode uses 4 to 90 impulses per second and the Myofascial mode can use anywhere from 30 to 50 impulses per second.  No other adjusting instruments have this much range. There is also an auto-rate setting for the osseous adjusting that changes the rate dependent upon the change in fixation during the adjustment which is being measured during each impulse.

The PulStar has 2 additional modes that are specifically used for extremities and soft tissue.  The Point mode starts at 4 impulses per second and sweeps up to 90 impulses per second. The Myofascial mode changes rate depending on the preload pressure and the rate can be held anywhere from 30 up to 50 impulses per second.

The PulStar has a preference setting to change from multiple-impulse analysis, up to 5 impulses at each site, to single impulse analysis mode. It is the doctor’s preference as to which option is used.

The PulStar does not have the older impact design of other adjusting instruments.  Instead, the PulStar uses an updated design called True Impulse™. This design mimics the manual adjustment of the Chiropractor but is many times faster. The True Impulse™ design is also much more quiet than older impact designs and allows the PulStar to use much higher frequencies to work with extremities and soft tissue.