Change PulStar preferences

Choose PulStar > Preferences (⌘,), then click a tab in the toolbar. Hold the pointer over any setting to see a short description of it.

Changes take effect right away. To keep your settings the same on all your Macs and iPads, turn on Sync Preferences on the General tab.

General

SettingWhat it does
Sync PreferencesSyncs these preferences through iCloud with your other Macs and iPads running PulStar.
Start App In Full ScreenOpens PulStar in full screen every time it starts.
Spine Background OpacityHow strongly the spine image shows behind the analysis bars. Drag left to fade it.
Show GridShows grid lines behind the analysis chart, spaced at 20% of its width, to help you spot vertebrae that differ from their neighbors by 20% or more.
Show Raw ReadingsShows the measured value next to each bar on the analysis chart.
Green Bars / Orange BarsShow green bars for intersegmental joints whose readings are in the normal range, and orange bars for joints just below the red-bar threshold.
Show Regional StiffnessHighlights regions of the spine whose readings are higher or lower than expected. Turning it on turns off Show Only High Regions and Show Only Low Regions, which highlight just one kind.
Zoomed View During Analysis / TreatmentShows an enlarged view of the readings during analysis, or of the selected vertebra's readings during treatment.
Preload As SpeedometerShows the preload as a speedometer-style dial during treatment. When this is off, the preload shows as a horizontal bar that fills from yellow to green to orange as preload builds.
Show Previous VisitShows the patient's previous visit beside today's analysis for comparison.
System BeepPlays a sound for each reading and when analysis or treatment readings finish. Turning it off silences all session sounds.
Announce SegmentsSpeaks the name of each spinal region during analysis, and each vertebra during treatment. Force changes and adjustment mode changes are always spoken, even when this is off, for safety.
Text To Speech Voice / Speech RateThe voice and speed used for spoken announcements. A sample plays when you change them.
Text SizeText size used in the patient list.
Adjustment TitleWhether treatment is labeled “Adjust” or “Mobilize” on screen and on printed reports.
Patient Required FieldsWhich details (name, number, or both) must be entered before a new patient can be saved.
Allow control from Apple WatchLets a paired Apple Watch control sessions on this Mac over Bluetooth. Reset Watch Access disconnects every paired watch. See Control PulStar with Apple Watch.
AcknowledgementsThird-party software used in PulStar and its licenses.

Display

Sets the background and text (foreground) colors for each spinal region on the analysis chart: cervical (C1–C7), thoracic (T1–T12), lumbar (L1–L5) and sacral. Notes Foreground sets the default text color for session notes, on screen and on printed reports. Reset to Defaults restores the original colors.

Session

SettingWhat it does
Auto Select VertebraHow many vertebrae to select for treatment automatically after analysis, starting with the most significant findings. Choose 0 to select them yourself.
Adjustment OrderThe order in which selected vertebrae are treated. Auto starts with the most significant finding; the other options follow the spine top to bottom or bottom to top.
PositionThe default patient position for analysis: prone, sitting or standing. A patient's own saved position is used instead when there is one.
Start In AdjustmentOpens sessions directly in treatment. While this is on, analysis is turned off: the Analysis and Compare modes are hidden, the Apple Watch cannot switch to analysis, and analysis charts are left out of session reviews and printed reports.
Start at L5Analyzes the lumbar spine from L5 upward instead of from L1 downward.
Display Primary Vertebra OnlyLabels findings by their primary vertebra instead of as the joint between two vertebrae.
Disable Post AnalysisSkips the post-treatment analysis. The post analysis is hidden, unless Replace Post with Adjusted is also on, which shows the readings taken during treatment in its place.
Auto Save Patient PreferencesRemembers the force used for each spinal region and makes it that patient's default at the next visit.
Adjustment Effective BeepBeeps when the impulses stop because the stiffness has stabilized, in Osseous mode. Requires System Beep.
Analysis ImpulsesNumber of impulses delivered at each vertebra during analysis.
Force defaultsDefault forces for analysis, for each spinal region, and for soft tissue. A patient's own saved force is used instead when there is one. Auto Save Soft Tissue Force updates the soft tissue default to the force last used.
Max Number Of ImpulsesThe most impulses delivered to one vertebra before the impulses stop: 100, 150, 200 or 999. In Osseous mode they can stop sooner, when the stiffness stabilizes. Myofascial mode always allows up to 999. You can stop at any time by lifting the impulse head.

Clinic

Your clinic's name, the doctor's name, and the address and phone number printed on patient reports. Clinic Email is the contact address for your PulStar account; it is not printed on reports.

Report

Printed Description is the text printed on patient reports to explain the PulStar analysis. Reset to Default restores the original text.

Email

Email Message is included when you email a report to a patient. Review Link adds a Google review link to the email: in your Google Business Profile, open Read Reviews, choose Get more reviews, then select Copy, and paste the full link, starting with https://.

DICOM

Connects PulStar to your imaging server (PACS) and sets how images are displayed and stored. See Connect to an imaging server.

Advanced

SettingWhat it does
Neuropatholator Password / DefaultThe password for the Neuropatholator anatomy content, and the screen it shows first.
Data FolderWhere PulStar stores patient data. Changes take effect right away, without restarting PulStar. See Patient data, sync and backups.
Clear Cache / Rebuild CacheDeletes cached data, or clears it and rebuilds it from your patient data. Patient data is not affected.
Red, yellow and selection thresholdsHow far a reading must be from the average, in standard deviations, to show as a red or yellow bar, or to be selected automatically for treatment. Post Behavior chooses which average post-analysis readings are compared against.
Soft Tissue/Extremity LocationsEdits the list of soft tissue and extremity locations offered during treatment.
Update Firmware / Run DiagnosticsInstalls the latest firmware on the connected PulStar, or runs a diagnostic check and sends the results to PulStar support. See Firmware and troubleshooting.
Preload ThresholdsViews or changes the device's preload thresholds. Change them only when advised by PulStar support.
Start Support CallStarts a FaceTime Audio call with PulStar support.
Important: The thresholds and preload settings change how findings are shown and how the device behaves. Leave them at their defaults unless PulStar support advises otherwise.